1 Display toggles between side "A" and side "B" | DIP switch 1 is turned on | Turn off switch |
Bad CPU | Replace CPU | |
Unit is in inspection mode | Press enter on remote | |
2 Head does not reset | Bad connection on optical handle switch | Plug in switch Re-do connections |
Faulty optical switch | Replace switch | |
Authorize circuit not wired properly | Rewire if necessary | |
Programmed as console but running as stand alone | Program as stand alone | |
3 Motor tries to start with handle switch off. | Sunlight getting to optical switch. | Cover switch |
Faulty controller TRIAC. | Replace power supply. | |
Broken connections on optical switch. | Repair connections or replace switch. | |
4 Console not receiving pulses. | Pulser wires reversed. | Correct wiring. |
Head programmed as pulser "Off". | Program for proper pulse width. | |
Jumpers JP4 and JP5 are reversed. | Check and reposition. | |
5 Head resets but motor will not start. | No power to motor Triac's. | Apply power to inputs. |
Faulty motor Triac's. | Replace power supply. | |
6 Head calls console for authorization event with handle off. | Incorrect wiring. | Correct wiring. |
Authorize line going to ground. | Repair short in wiring. | |
Authorize line overloaded. | Add snubber circuit Part #DH-EQ-snubber. | |
7 Cannot read totals or program head. | Main display wiring harness reversed. | Reverse harness wiring. |
Faulty programmer. | Replace batteries Replace programmer | |
Faulty receiver on main display. | Replace main display. | |
8 Stand alone pump starts but stops after a short time, resets and starts again. See 17. | If only one circuit at pump for everything, Fluorescent tube or ballast bad. | Isolate other circuits from pump head power. |
If Head power drops to less than 80 volts the computer will reset If motor is on the same circuit it may be drawing too much power | Put Head on its own power circuit. | |
Optical switch faulty. | Replace optical switch. | |
9 Console pump starts okay but stops after short time, resets and calls in for authorization repeatedly. | Optical handle switch bad connection. | Replace optical switch. |
10 Stand alone pump starts and stops while dispensing. See 17. | Motor overload. | Check breaker for motor power. |
11 Display flashes erratically, strange characters appear | Bad connections on wire harness or display board. | Check connections on harness. Replace display board. |
12. Console counts wrong amount of pulses from head. | Pulse output from head does not match console. | Program pulse output in memory section(03) until both units agree. |
Pulser output fault, caused by wiring fault. | Repair wiring then check for proper operation. If not: replace power supply. | |
13 Console or card system miscounts by multiple of 10,100,1000. | Pulse output programmed incorrectly. | Program section (62) for correct ppu amount. |
14 Temperature probe B reads 3-10 degrees high or low on a 2 hose single product pump with two probes. | Pump is programmed incorrectly. If programmed as 2 hose 1 product section (65) head will not read the second probe. | Program pump as a 2 hose 2 product in section (65). |
15 Pump shuts off at the same amount every time. | Head is programmed for either a volume limit or a dollar limit in sections (06) or (07). | To clear any presets enter sections (06) and (07) with all 9's. |
16 Display shows ADC fail. | Hardware failure on the CPU board. | Replace CPU unit. |
17 No response from handle switch in stand alone mode or console mode. No display change or flash. | CPU Hardware fault. | Replace CPU after checking for wiring or switch faults. Check section (18) for diagnostic display of handle status. |
18 After turning handle switch on nothing happens. | Handle switch may be plugged into the wrong connector. | Check and reverse handle connectors for handle switch. |
19 Head rests normally but does not count pulses. | Pulser may be plugged into the wrong connector. | Check and reverse pulser connectors into the CPU. |
APPENDIX C - TYPICAL PUMP SETTING
Example #1: TOKHEIM TWO HOSE TWO PRODUCT ON A CONSOLE
02 - Penny Console
03 - Penny .004
12 - CCL (counter clockwise)
60 - Gal.-Lt. 4 turns (Imperial Grey Meter)
60 - 512 pt. 2 turns (Metric-Green Meter)
62 - 10 PPU
65 - 2 Hose 2 Product
Example #2: RDR HIGH VOLUME PUMP ON DIEBOLD SYSTEM
01 - Non Price
02 - Penny Console
03 - Vol .002
12 - CL (clockwise)
60 - 500 Pt. 1 Turn
62 - 100 PPU
63 - Vol DP 4
65 - 1 Hose 1 Product
Example #3: BENNETT 2 HOSE 1 PRODUCT STAND ALONE
02 - Stand Alone
12 - CCL (counter clockwise)
60 - 512 Pt. 2 Turn
65 - 2 Hose 2 Product
(NOTE: Both motor input leads must be joined together and motor output leads must be joined together, even if the pump is a 2 hose 1 product, if two probes are used. It must be programmed as a 2 hose 2 product to enable the second probe.)
TYPICAL METER SETTINGS
Tokheim Imperial (Grey) Gal Lt 4 Turn CCL
Tokheim Metric (Green) 512 PT 2 Turn CCL
Bennett 512 PT 2 Turn CCL
Gilbarco,Wayne Gal Lt 4 Turn CCL