Vaporless Manufacturing,Inc Leak Detectors Models 99/LD2000, 99/LD2200,99/LD3000
99/LD2000 • Available for Gasoline, Diesel, Alcohols, Bio diesel, Aviation • For any Pump • Electronic Interface Available • Longest length Pipeline System • Largest Volume Pipeline System • Integrated Check Valve / Pressure Relief • Field Adjustable Leak Threshold 99/LD2200 • Available for Gasoline, Diesel, Alcohols, Bio diesel, Aviation • For any Pump • Longest length Pipeline System • Largest Volume Pipeline System • Field Adjustable Leak Threshold 99/LD3000 3" • Available for Gasoline, Diesel, Alcohols, Bio diesel, Aviation • For any Pump • Combined Rigid and Flexible Pipe System up to 502 Gallons • Rigid Pipe only up to 406 Gallons • Longest length Pipeline System • Smallest Profile • Integrated Check Valve / Pressure Relief • Field Adjustable Leak Threshold Vaporless Manufacturing,Inc Leak Detector Testers Models LDT-890 and LDT-890AF
• Factory Certification for Catastrophic Annual Testing and Troubleshooting • LDT-890\AF for Alcohols, Bio diesel and some chemical applications • Ensures regulatory compliance • Performs 3 GPH @ 10 PSI • Precision or Functional Test • Performs System Diagnostics; trouble shooting • Accurate Viscosity adjusted leak rate Vaporless Manufacturing,Inc Automatic Repressurization Module Model ARM-4073
• Works with any 99/LD2000 or 99/LD3000 VMI Leak Detector • LDT-890\AF for Alcohols, Bio diesel and some chemical applications • All Submersible Pumps • Compensates for fixed solenoid delays • Automatic re pressurization at daily start up Vaporless Manufacturing,Inc Fuel Transfer Controllers Models AST-4010 and AST-4012
• AST-4010 Single Tank or AST-4012 Dual Tank • High Level Warning - Shut Down and Alarm • High Level Alarm - SHut Down and Lockout • No Hydraulic Hammer • No Valve restrictions • Regulator compliance - empty transfer hoses • Controls motors up to 25 HP • Alarm Circuit / Alarm Relays • Enclosure meets or exceeds U.L. Class 1, Group D Hazardous Environment Criteria Vaporless Manufacturing,Inc Overfill Protection Valves Models OFP-2/1, OFP-2/2, OFP-3/1 and OFP-3/2
• For Above Ground Storage Tanks • Meets Uniform Fire Code • Meets NFPA code 30A requirements for complete shutdown @ 98% fuel level • Model 2\1: One 4" tank opening required. Shutdown Valve and Pilot Valve mount on a 4" x 2" male pipe thread bushing (provided). For use with 2" drop tube only • Model 2\2: Requires two tank openings; one opening may be 2" or 3" and the second opening should be 4" (two 4" openings are acceptable). 4" pipe thread bushing provided. Requires a minimum of one 2" and one 4" opening • MODEL 3\1: One six inch tank opening required, OFP Valve and Pilot Valve mount on 6" male pipe thread Bushing provided. For use with 3" drop tube only • MODEL 3\2: Requires two tank bung's. Combinations of : 2 - 4" bung's or 1 - 3" bung and 1 - 4" bung. Consult factory for other combination or custom configurations. One 4" male NPT Bushing provided to install Pilot Valve and to vent OFP Valve. For use with 3" drop tube only
Page Last Updated: Thu, 30 Sep 2010