Troubleshooting Tips No. 18 - Installing PIcon-K Progressive International Console with Kraus Micon & MTI (D&H) EQ30 or EL6.0 Heads - Issues
We have discovered a number of conditions where the PIcon Console will not work or work correctly with both Kraus Micon Heads and MTI (D&H) EQ30 Heads. We will deal with each of these below:Kraus Micon Heads
Micon 100MTI (D&H EQ30 HeadsSKIL 152 A15 Board and must have version DANPMP3.1 or DANPMP3.2 Software.Micon 200
SKIL 421 boards must have version V7.03 Software.SKIL 252 Boards must have version V6.3 Software. Note! Will not work on two tier pricing!Micon 500
SKIL 350 Boards must have version V7.03 or V1.09 Software. Note! Will not work on two tier pricing!Units must have version V1.33 Software and be equipped with the optional piggyback SKIL 472 MNET Interface Board to provide serial interface. Note! Will not work on two tier pricing!CPU BoardMust have version V1.42 Software in order for shift reports to function properly.MTI EQ30 Power Supply
Must be Revision 3 or 4 or a "Modified" Revision 1 or 2 board are required for Kraus MNET communication.All boards show revision 2 on the front of the board and the actual Revision number is only marked on the rear of the board. Therefore for quick identification refer to Figure 1. Once you have established that you have a Revision 1 or 2 Board you will have to remove it from the Explosion Proof housing to determine if it is modified. Modified version 1 or 2 boards will have a transistor and 2 resistors soldered to the back of the board behind the Microprocessor U1.
If R8 is 30K (Orange/Black/Orange Bands or check with ohmmeter) needs to be 1.0K (Brown/Black/Red Bands)
If R9 is 30K (Orange/Black/Orange Bands or check with ohmmeter) needs to be 1.0K (Brown/Black/Red Bands)MTI EL6.0 Power Supply
If R24 is 30K (surface mount check with ohmmeter) needs to be 1.0K
If R25 is 30K (surface mount check with ohmmeter) needs to be 1.0KNote! If the above Power supplies are 30K you will need to change them. We have a special exchange price on these provided nothing else is wrong with the Power Supply. Contact us immediately!
Figure 1
Wiring to the C2000K is also different for the Various Revisions:Revisions 1, 2, 3 and Revision 4 with JP1 installed :Com 1 (Red 22 Ga) #11 = DCC (Data Channel Common)Revision 4 with JP1 Removed:
Com 2 (Blk 22 Ga) #12 = TTP (Transmit to Pump)
Com 3 (Grn 22Ga) #13 = TTC (Transmit to Console)Com 1 (Red 22Ga) #11 = DCC (Data Channel Common)For All Power Supplies Jumpers JP4 and JP5 must be set as follows:
Com 2 (Blk 22 Ga) #12 = TTP (Transmit to Pump)
Com 4 (Yel 22Ga) # 1 = TTC (Transmit to Console)JP4 = *-* * (shunt 1 & 2) (To the left)
JP5 = * *-* (Shunt 2 & 3) (To the right)
Download NPDL Wiring Diagram A00378 - Installing with Kraus Micon 100
Download NPDL Wiring Diagram A00379 - Installing with Kraus Micon 200 and 500
Download NPDL Wiring Diagram A00385 - Installing with MTI (D&H) EQ30 Revision 1 Power Supply and Harness
Download NPDL Wiring Diagram A00384 - Installing with MTI (D&H) EQ30 Revision 2 & 3 Power Supply and Harness
Download NPDL Wiring Diagram A00386 - Installing with MTI (D&H) EQ30 Revision 4 Power Supply and Harness
Download EQ30 Wiring Harness Color and Pin Out for various Power Supply Revisions Various EQ30 Harness